User Tools

Site Tools


blog:replace_faulty_disk_in_linux_md

Replace faulty disk in linux md

Replacing a faulty drive in an mdadm managed RAID array.

  1. Use 'mdadm –manage /dev/mdX -r /dev/sdF' to remove the drive that was marked as faulty from the array.
  2. Power down and replace the drive with a good drive.
  3. Power up and set the partition table on the new drive to match those of the other drives in the array. Here we used 'sfdisk -d /dev/sdN | sfdisk /dev/sdF'.
  4. Add the proper partition on the new drive into the array, 'mdadm –manage /dev/mdX -a /dev/sdN2'
  5. Sit back and wait for the recovery to happen. The system will be a bit slow but usable.

Ref:

~~LINKBACK~~

Discussion

Enter your comment. Wiki syntax is allowed:
   ___    ____   _  __   __ __   ___ 
  / _ \  / __/  | |/_/  / //_/  / _ \
 / , _/ / _/   _>  <   / ,<    / // /
/_/|_| /_/    /_/|_|  /_/|_|  /____/
 
blog/replace_faulty_disk_in_linux_md.txt · Last modified: 2014-01-04 11:56 by brb