User Tools

Site Tools


blog:replace_faulty_disk_in_linux_md

This is an old revision of the document!


Replace faulty disk in linux md

Replacing a faulty drive in an mdadm managed RAID array.

  1. Use “mdadm –manage /dev/md0 -r /dev/sdd” to remove the drive that was marked as faulty from the array.
  1. Power down and replace the drive with a good drive.
  1. Power up and set the partition table on the new drive to match those of the other drives in the array. Here we used “sfdisk -d /dev/sda | sfdisk /dev/sdd”.
  1. Add the proper partition on the new drive into the array, “mdadm –manage /dev/md0 -a /dev/sdd2”
  1. Sit back and wait for the recovery to happen, you can “cat /proc/mdstat” to watch its progress; you should see something like: